F-4300 Clamp-on Ultrasonic Flow Meter & Thermal Energy Measurement System

The ONICON F-4300 provides accurate flow and thermal energy measurement without cutting or modifying the existing pipe. Its non-invasive clamp-on design makes it particularly suitable for HVAC retrofit projects, system monitoring and operational facilities where shutdowns are not practical.

Pipe Size: ½" to 48". Communication: RS485, BACnet® MS/TP, MODBUS® RTU. Applications: Chilled water, hot water, domestic water, condenser water and boiler feed water

  • Manufacturer: ONICON (USA)
  • Origin: USA
  • Authorized Distributor: PGTECH Vietnam
Thêm vào giỏ hàng
Liên hệ mua hàng
Mô tả sản phẩm
Đặc tính thiết kế
Tải tài liệu
Đánh giá

Mô tả sản phẩm

The ONICON F-4300 Clamp-on Ultrasonic Flow Meter & Thermal Energy Measurement System is a high-accuracy solution for measuring hydronic water flow and thermal energy without making direct modifications to the existing piping system.

Using a pair of externally mounted ultrasonic sensors and advanced signal processing technology, the F-4300 measures flow through the pipe wall without requiring pipe cutting, welding or interruption of the existing flow. This makes the system particularly suitable for existing HVAC installations, retrofit projects and performance monitoring applications where shutting down the system is undesirable or impractical.

The F-4300 supports pipe sizes from ½" to 48", providing flexibility for a wide range of chilled water, hot water and hydronic system applications. The clamp-on sensor configuration also eliminates the pressure loss typically associated with inserting a primary flow element directly into the piping system.

The system is designed with optimized ultrasonic sensors and user-friendly hardware to provide stable measurement performance under different pipe conditions. Sensors can be configured according to the application and pipe characteristics to achieve a strong signal-to-noise ratio and reliable measurement.

For thermal energy measurement, the F-4300 combines flow measurement with temperature measurement to calculate thermal energy consumption in hydronic systems. This makes it suitable for monitoring HVAC energy performance, evaluating system operation and supporting energy management programs.

The F-4300 also features 128 MB of integrated data logging capacity, allowing measurement data to be stored for performance evaluation and baseline monitoring. This is particularly useful during HVAC retrofit projects where operators need to establish existing system performance before implementing upgrades.

The system supports RS485 communication with BACnet® MS/TP or MODBUS® RTU, allowing measured data to be integrated directly into BMS and BAS platforms for centralized monitoring and energy management.

The F-4300 is configured by ONICON based on the application information provided by the customer, helping simplify installation and reduce the amount of programming required in the field.

Đặc tính thiết kế

  • Non-invasive clamp-on design allows flow measurement without cutting, welding or interrupting the pipe.
  • Suitable for pipe sizes from ½" to 48".
  • Ideal for HVAC retrofit and existing-system monitoring where system shutdown is not practical.
  • Measures both water flow and thermal energy for hydronic applications.
  • External sensors eliminate the need for intrusive installation and minimize pressure loss.
  • Application-optimized ultrasonic sensors provide stable signals and reliable measurement.
  • Integrated 128 MB data logger supports baseline and performance monitoring.
  • Factory configured according to application data for simplified commissioning.
  • RS485 communication supports BACnet® MS/TP and MODBUS® RTU.
  • Suitable for direct integration with BMS/BAS platforms.
  • Applicable to chilled water, hot water, condenser water, domestic water and boiler feed systems.
  • Well suited for energy monitoring, system diagnostics and HVAC performance evaluation.

Tải tài liệu

F-4300 Catalog Sheet

 
Hotline Message Gmail Zalo